Battery Group Reference Data

Entity database of battery groups — click a group for its full entity page (specification + evidence). Values are cross-verified ranges, not a substitute for a specific battery’s datasheet.

⚠️ CCA basis matters — a JIS number (tested at −15°C) reads higher than an EN/SAE number (tested at −18°C) for the same battery. Compare only within one standard.

Group Alias Standard Voltage Capacity (Ah) CCA CCA basis Technology
H4 L1 EN/DIN 12V 55–60 500–600 A EN 50342 (−18°C) Flooded / EFB / AGM
H5 L2 EN/DIN 12V 60 600 A EN 50342 (−18°C) Flooded / EFB / AGM
H6 L3 EN/DIN 12V 70 640–700 A EN 50342 (−18°C) Flooded / EFB / AGM
H7 L4 EN/DIN 12V 70–80 760 A EN 50342 (−18°C) Flooded / EFB / AGM
H8 L5 EN/DIN 12V 90–95 850–900 A EN 50342 (−18°C) AGM / EFB
H9 L6 EN/DIN 12V 105 950 A EN 50342 (−18°C) AGM / EFB
55D23 D23 JIS 12V 60 540 A JIS D5301 (−15°C) Flooded MF
N150 145G51 JIS 12V 135 900 A JIS D5301 (−15°C) Heavy-duty flooded
N200 190H52 JIS 12V 200 1100 A JIS D5301 (−15°C) Heavy-duty flooded
Group 31 31 BCI/SAE 12V 100 900 A SAE J537 (−18°C) Flooded / AGM
Group 8D 8D BCI/SAE 12V 200+ 1400+ A SAE J537 (−18°C) Heavy-duty flooded
Group 24 24 BCI/SAE 12V 70–75 700 A SAE J537 (−18°C) Flooded / AGM
Group 27 27 BCI/SAE 12V 90–95 800 A SAE J537 (−18°C) Flooded / AGM
Group 4D 4D BCI/SAE 12V 160–180 1100 A SAE J537 (−18°C) Heavy-duty flooded
65D23 D23 JIS 12V 65 580 A JIS D5301 (−15°C) Flooded MF
N70 65G24 JIS 12V 70 700 A JIS D5301 (−15°C) Flooded MF
N100 95E41 JIS 12V 100 800 A JIS D5301 (−15°C) Heavy-duty flooded
N120 115F51 JIS 12V 120 900 A JIS D5301 (−15°C) Heavy-duty flooded
Group 34 34 BCI/SAE 12V 55–75 750–900 A SAE J537 (−18°C) Flooded / AGM
Group 49 H8 BCI/SAE (DIN/EN H8) 12V 80–95 850–950 A SAE J537 (−18°C) Flooded / AGM / EFB
Group 65 65 BCI/SAE 12V 70–75 750–950 A SAE J537 (−18°C) Flooded / AGM
GC2 Golf cart BCI 6V 215 — A Not cranking-rated (deep-cycle) Flooded deep-cycle
GC12 12V golf cart BCI 12V 150 — A Not cranking-rated (deep-cycle) Flooded deep-cycle
Group 25 25 BCI/SAE 12V 45–60 550–650 A SAE J537 (−18°C) Flooded / EFB / AGM
Group 26 26 BCI/SAE 12V 45–55 500–550 A SAE J537 (−18°C) Flooded / EFB / AGM
Group 35 35 BCI/SAE 12V 45–60 550–650 A SAE J537 (−18°C) Flooded / EFB / AGM
Group 48 H6 BCI/SAE (EN H6) 12V 70 700–760 A SAE J537 (−18°C) Flooded / EFB / AGM
Group 51 51 BCI/SAE 12V 45–50 450–500 A SAE J537 (−18°C) Flooded / EFB / AGM
Group 58 58 BCI/SAE 12V 50–55 500–550 A SAE J537 (−18°C) Flooded / EFB / AGM
Group 75/25 75/25 BCI/SAE 12V 50 500–550 A SAE J537 (−18°C) Flooded / EFB / AGM
Group 78 78 BCI/SAE 12V 55–65 700–800 A SAE J537 (−18°C) Flooded / EFB / AGM
Group 94R H7 BCI/SAE (EN H7) 12V 80 800–850 A SAE J537 (−18°C) Flooded / EFB / AGM
Group 96R 96R BCI/SAE 12V 50 550–600 A SAE J537 (−18°C) Flooded / EFB / AGM
75D23 75D23L JIS 12V 65 600–650 A JIS D5301 (−18°C) Flooded
80D26 80D26L JIS 12V 70 650–700 A JIS D5301 (−18°C) Flooded
95D31 95D31L JIS 12V 80 750–800 A JIS D5301 (−18°C) Flooded
115D31 115D31L JIS 12V 90 850–900 A JIS D5301 (−18°C) Flooded
130D31 130D31L JIS 12V 95 900–950 A JIS D5301 (−18°C) Flooded
55B24 55B24L JIS 12V 45 400–450 A JIS D5301 (−18°C) Flooded
40B19 40B19L JIS 12V 28–30 300–350 A JIS D5301 (−18°C) Flooded